Adrona

Water Purification Systems

Adrona is a leading producer of economical as well as highly sophisticated water purification systems for a wide range of laboratory applications, including trace analysis, HPLC, flow cytometry, wet chemistry as well as ultrapure water with very low organic and RNase / DNase content. System features include tank filling control, tap water pressure control, boost pump, reverse osmosis and deionization modules, 25 liters storage tank with integrated dispensing pump, UV sterilization module, ultrafilter and photo-oxidation module for the elimination of organics.


Adrona
Conductivity (Grade 3): <5 µS/cm
Particles (>0,22 µm): <1 per ml
Nominal flow to storage tank: 7 - 10 l/h

The Crystal 7 (reverse osmosis) systems produce purified water for general laboratory applications such as feed water for labware washers or glassware rinsing. 'Sterifeed' is a water purification (Grade 3) system which is designed to produce feed water for autoclaves.

Grade 3 water produced by these systems complies with ISO 3696, ASTM and CLSI standards. More information

Adrona
Conductivity (Grade 2): <0,1 µS/cm
TOC: <30 ppb
Particles (>0,22 µm): <1 per ml
Nominal flow to storage tank: 28 l/h

The Crystal Clinic / Crystal Pure water purification system is designed to provide purified water for automated biochemistry analyzers. Pure water (Grade 2) is typically needed for sensitive, inorganic analytical applications including electrochemistry, flame AAS, wet chemistry, spectrophotometry, buffer and media preparation.

Grade 2 water produced by these systems complies with ISO 3696, ASTM and CLSI standards. More information

Adrona
Conductivity (Grade 1): <0,055 µS/cm
TOC: <5-10 ppb
Bacteria: <1 CFU/ml
Endotoxins: <0,001 EU/ml
Particles (>0,22 µm): <1 per ml

The Crystal Trace ultrapure water systems produce water for inorganic trace analysis. Such water is recommended for graphite AAS (atomic absorption spectrometry), ICP-OES analysis, ICP-MS, reagent preparation and ion chromatography.

Grade 1 water produced by these systems complies with ISO 3696, ASTM and CLSI standards. More information

Adrona
Conductivity (Grade 1): <0,055 µS/cm
TOC: >2 ppb
Bacteria: <1 CFU/ml
Endotoxins: <0,001 EU/ml
Particles (>0,22 µm): <1 per ml

The Crystal HPLC and Integrity+ HPLC systems provide ultrapure water meeting the requirements of liquid chromatography methods. Water produced by Onsite HPLC and Connect HPLC is intended for organic analysis methods such as liquid chromatography, gas chromatography, mass spectrometry, molecular biology, TOC measurement, HPLC and UHPLC.

Grade 1 water produced by these systems complies with ISO 3696, ASTM and CLSI standards. More information

Adrona
Conductivity (Grade 1): <0,055 µS/cm
TOC: <2 ppb
DNase: <4 pg/µl
RNase: <0,01 ng/ml
Bacteria: <1 CFU/ml
Endotoxins: <0,001 EU/ml
Particles (>0,22 µm): <1 per ml

The Crystal Bio and Integrity+ Bio systems produce ultrapure water right from tap water. Water is purified in two stages: pure water is produced first and stored in the tank. Pure water is later used for production of ultrapure water, used for highly sensitive biological and chemical applications like flow cytometry, cell and tissue culture and molecular biology.

Grade 1 water produced by these systems complies with ISO 3696, ASTM and CLSI standards. More information